8 Parameter detail setup
120 © Copyright Reserved Autonics Co., Ltd.
8.8.1 Load Set File (Open parameter setting file)
Applies set value of saved parameter set file.
When applying this set, backup data, user unit and booting logo are not changed.
None, Default.pms file is activated and if there is User1.pms to User5.pms, User1.pms(USB) to
User5.pms(USB) file(parameter set save file), it is activated.
Setting range: None ↔ Default.pms ↔ User1.pms to User5.pms ↔ User1.pms(USB) to
User5.pms(USB)
Factory default: None
Be sure that if selecting ‘Default.pms’ file, every set value is reset as factory default. Save the
current set parameter as Save Set File (parameter setting file storage) at first and reset it for the
provision.
User1.pms to User5.pms, User1.pms(USB) to User5.pms(USB) file is selected, all parameter
setting information of KRN100 is changed as the set value of the selected parameter save file.
Set value changing may be also affected to every setting of KRN100’s overall operations. Check
possible problems occuring on system and change the desired set value.
8.8.2 Save Set File (Save parameter setting file)
Saves current set parameter set value to User1.pms to User5.pms file of inner memory.
In case of empty file, it displays gray.
Setting range: None ↔ User1.pms to User5.pms, User1.pms(USB) to User5.pms(USB)
Factory default: Select …