8 Parameter detail setup
© Copyright Reserved Autonics Co., Ltd. 123
When connecting an USB memory, KRN100 pauses backup data download by Modbus function,
and backup data printer function to recognize memory for a while (dending on the capacity, max.
30 sec).
If an USB memory’s LED flashes, do not remove an USB memory, or it may damage to the data.
If the damage of USBmemory data occurs, you can find the saved data from KRN100 inner
memory and save the desired file to an USB memory.
Set USB LogData Save(USB storage function) as ‘Disable’ and when the below message
disappears, remove an USB memory.
8.8.6 Memory Save Option (Memory storage option)
Set the operation how to storage new data when inner memory storage space is used all as
100%.
Overwrite
Deletes the oldest backup data file in order and saves new data.
Important backup data should be backup at first.
Stop(Stop saving)
Stops backup data.
It does not save Backup data. Even though new recording paper is
replaced, output function for backup data does not operate.
Setting range: Overwrite ↔ Stop
Factory default: Stop