8 Parameter detail setup
104 © Copyright Reserved Autonics Co., Ltd.
8.5.7 Standard Period (Standard record period)
Set record period to record current time, display value by channel as digital number on recording
paper.
It is actiaved when Record Mode(Record mode) is Digital.
Setting range: 00m 01s to 99m 59s (Depending on the number of recording channel, min.
setting range is limited as below.)
Record channel
Setting range
Record channel
Setting range
1 to 2 01m 00s to 99m 59s 7 to 8 04m 00s to 99m 59s
3 to 4 02m 00s to 99m 59s 9 to10 05m 00s to 99m 59s
5 to 6 03m 00s to 99m 59s 11 to 12 06m 00s to 99m 59s
Factory default: -
8.5.8 Option Period (Option record period)
When Record Mode(Record mode) is set as Digital, set record period for current time
(hh:mm:ss) and measuring value by channel (min:sec) through digital input(Speed set).
Setting range: 00m 01s to 99m 59s (Depending on the number of recording channel, min.
setting range is limited as below.)
Record channel
Setting range
Record channel
Setting range
1 to 2 01m 00s to 99m 59s 7 to 8 04m 00s to 99m 59s
3 to 4 02m 00s to 99m 59s 9 to 10 05m 00s to 99m 59s
5 to 6 03m 00s to 99m 59s 11 to 12 06m 00s to 99m 59s
Factory default: -