Parameter Lists
83
890053-00-02
Code
Name
LCD Display
Setting Range
Initial value
Property*
Ref.
11
Jog frequency
Jog Frequency
0.00, Low FreqHigh Freq
10.00
O
p.165
12
Jog acceleration time
Jog Acc Time
0.0600.0 (sec)
20.0
O
13
Jog deceleration time
Jog Dec Time
0.0600.0 (sec)
30.0
O
15
Torque boost options
Torque Boost
0
Manual
0
Manual
Δ
p.117
1
Auto 1
2
Auto 2
16
3
Forward Torque boost
Fwd Boost
0.015.0 (%)
2.0
240V, 480V
7.5~125HP
Δ
p.117
1.2
575V
7.5~150HP
1.0
480V
150~800HP
17
Reverse Torque boost
Rev Boost
0.015.0 (%)
2.0
240V, 480V
7.5~125HP
Δ
p.117
1.2
575V
7.5~150HP
1.0
480V
150~800HP
19
Start frequency
Start Freq
0.0110.00 (Hz)
0.50
Δ
p.120
20
Maximum frequency
Max Freq
40.00-400.00 (Hz) 240V,
480V
60.00
Δ
p.120
40.00-120.00 (Hz) 575V
40.00-120.00 (Hz)
IM Sensorless
2
p.120
40.00-180.00 (Hz)
PM Sensorless
2
p.120
21
Select speed unit
Hz/Rpm Sel
0
Hz Display
0
Hz Display
O
p.120
1
RPM Display
22
4
Auto torque boost filter
gain
ATB Filt Gain
1 9999 (msec)
10
O
p.117
23
Auto torque boost voltage
ATB Volt Gain
0.0-300.0%
100.0
O
p.117
25
Hand mode operation
frequency
HAND Cmd Freq
0.00, Low Freq- High Freq
0.00
O
p.64
26
Hand mode operation
Frequency reference
source
HAND Ref Mode
0
HAND Parameter
0
HAND Parameter
Δ
p.64
1
Follow AUTO
30
kW/HP unit selection
kW/HP Unit Sel
0
kW
1
HP
O
p.120
1
HP
31
Quick Start
PopUp Q.Start
0
No
0
No
X
p.52
1
Yes
95
Inverter Temperature
Temperature
XXX °C
X
-
96
Inverter Software Version
Inv S/W Ver
201.00
X
-
97
Inverter Software Version
Inv Debug Ver
0.02
98
I/O Software Version
I/O S/W Ver 1
201.00
99
I/O Software Version
I/O S/W Ver 2
0.00
[1] ‘10(V3) and 11(I3)’ of DRV-07 are available when Extended IO Bd. is installed. Refer to Extended IO option manual for more detailed
information.
[2] IM Sensorless: Does not apply to 230V, 30~125 HP inverters.
PM Sensorless: Does not apply to 230V, 30~125 HP, 460V, 150~800 HP and all 575V Inverters.
[3] DRV-16,17 are displayed when DRV-15 is set to ‘0 (Manual)’.
[4] DRV-22, 23 are displayed when DRV-15 is set to 'Auto-2'.

Table of Contents

Related product manuals