C8000 Battery Testing System User Manual
Battery Tester 27
All Standard Battery Types
Lead Acid
Ni-based: NiMH, NiCd
Li-based: Li-ion, Li-Phosphate
Nominal 1.2V-36V (max 45V) supports serial
connection of:
Up to 10 Li-ion cells (3.6V/cell)
Up to 18 Lead Acid cells (2.0V/cell)
Up to 30 Nickel-based cells (1.2V/cell)
100W per channel = 400W total
Maximum Discharge Power
80W per channel = 320W total
Dual Power Port cable may be to increase the
maximum Power Rate to 160W per channel pair
External Load may be used to increase
Discharge Rate up to 2400W
Maximum Charge/Discharge
Current
30mA to 10A set in 1mA increments
Dual Power Port cable may be to increase the
maximum Discharge Rate to 20A per channel
pair
External Load may be used to increase
Discharge Rate up to 240A
Square 2 kHz (500 microseconds)
Voltage = 0.1% full scale
Current = 0.25% full scale
Current automatically scaled down if power
limits are exceeded – message indicates scaled
test
Charge methods are dependent upon chemistry:
Li-ion + Lead Acid = constant current/