4021470 Rev D D9854 Advanced Program Receiver Installation and Operation Guide 4-83
Setup Menu: Outputs: TS Out: DPM, Continued
10. Press MENU three times to exit the TS Out menu and save the data. If the
changes cannot be saved/made, a message will be displayed indicating “Bad
configuration data”. The following options are available: Abandon, Exit or
Return. Select Return to re-enter the parameter.
Note: When remapping an input program channel to an output channel, ensure
that the PIDs are mapped to different PIDs to avoid PID collisions.
PE Resync: All, Template, PIDs, Svcs
Description: Each PE output can be synchronized to its input according to one of
four output modes.
Parameters: Services only (Svcs), PIDS only (PIDs), using a Template or All
(Services and PIDS).
Parameter Description
SIT Pass
ECM Drop
EMM Drop
DRT Drop
CDT Drop