Chapter 54 Configuring ASLB
Troubleshooting the ASLB Configuration
LocalDirector set commands did not take
effect.
The set lda commands do not take effect until you enter the commit lda
command.
You can verify which set lda commands are in effect by entering the show lda
commit command.
You can determine which set lda commands are set but not committed or what
changes will occur if the current set lda commands are committed by entering the
show lda uncommitted command.
You see “collisions” or “port disabled”
on the Catalyst 6500 series switch port.
Ensure that the port speed and duplex settings are compatible on both ends of the
link between the LocalDirector and the switch. For example, if port 3/7 on the
switch is connected to interface ethernet 0 on the LocalDirector, make sure that
port 3/7 is set to 100full and that interface ethernet 0 on the LocalDirector is also
set to 100full.