21-8
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
OL-8978-04
Chapter 21 Configuring GOLD
Configuring Online Diagnostics
After running the test:
For supervisor engines—Reboot the switch but do not save the configuration while rebooting
because the configuration was changed during the test.
For other modules—Power cycle the modules. After the modules come online, reenable the
health-monitor tests that were disabled.
Configuring Diagnostics Operations
You can specify that the on-demand online diagnostics continue to run until a configurable number of
failures occur by entering the continue failure_limit keyword. The failure_limit range is 0 to
65534 failures. You can specify that the on-demand online diagnostics stop running when a single failure
occurs by entering the stop keyword. You can specify that an on-demand test be run multiple times by
entering the iterations number_of_iterations keyword. The number_of_iterations range is 1 to 999.
The complete syntax for these commands is as follows:
set diagnostic ondemand action-on-failure [continue failure_limit | stop]
set diagnostic ondemand iterations number_of_iterations
Configuring Online Diagnostic Health-Monitoring Tests
You can configure health-monitoring diagnostic testing on specified modules while the switch is
connected to a live network. You can specify the execution interval for each health-monitoring test,
whether or not to generate a system message upon test failure, or whether an individual test should be
enabled or disabled.
The disruptive tests are disabled by default. A set number of nondisruptive tests (not all) are enabled by
default. Use the show diagnostic content module mod_list command to determine which tests are
disruptive (D) and nondisruptive (N) by checking the “Attributes” column. Use this information for
configuring additional health-monitoring tests. We recommend that you use only nondisruptive tests for
health monitoring.
To configure online diagnostic health-monitoring tests, perform this task in privileged mode:
This example shows how to specify that the online diagnostic health-monitoring tests (test 18) be run on
module 7 at 12:12:12 and 100 milliseconds every 10 days:
Console> (enable) set diagnostic monitor interval module 7 test 18 12:12:12 100 10
Diagnostic monitor interval set at 12:12:12 100 10 for module 7 test 18
Task Command
Step 1
Specify the online diagnostic monitoring interval. set diagnostic monitor interval module
mod_num test {all | test_ID_num | test_list}
hh:mm:ss
1
1. For the interval keyword, the range of milliseconds that can be specified is 0 to 999 and the number of days specified is 0 to 20.
Step 2
(Optional) Enable health-monitoring diagnostic
tests.
set diagnostic monitor module mod_num test
{test-id | test-id-range | all}
Step 3
Enable syslog generation when a test fails. set diagnostic monitor syslog
Step 4
Display the online diagnostic monitoring
configuration.
show diagnostic content module {mod_list | all}