23-54
Catalyst 6500 Series Switch Software Configuration Guide—Release 8.7
OL-8978-04
Chapter 23 Configuring Redundancy
MSFC Redundancy
Step 9 From the standby MSFC’s ROMMON prompt, repeat Step 3 but in Step 3d, select option 2 “boot system”
as follows:
change the boot characteristics? y/n [n]: y
enter to boot:
0 = ROM Monitor
1 = the boot helper image
2-15 = boot system
[2]: 2 <========================
Configuration Summary
enabled are:
load rom after netboot fails
console baud: 9600
boot: the ROM Monitor
do you wish to change the configuration? y/n [n]: n
You must reset or power cycle for new config to take effect
rommon 2 >
Step 10 Enter the reset command at the ROMMON prompt to boot the system.
Step 11 Once the MSFC has booted, enter the config-register 0x2102 command from Cisco IOS configuration
mode on the newly active MSFC’s console port.
Step 12 Press Ctrl-C three times to return to the supervisor engine prompt.