ComNav Commander P2 & P2VS Installation & Operation Settings & Notes
Document PN 29010074 V4.1 - 221 -
Parameter Range Default Value User Settings 1 User Settings 2
Work Menu
Rudder Bias
Auto/Nav rudder limit
or physical limit
Set at Runtime
Autotrim Off, On Off
Work Trip Pt. 1 – 10 2
Rudder Scale 0.25 – 3.00 (in 0.25 steps) 1.00
Work Mode State A_Rdy, A_On, M_Rdy, M_On
Set at Runtime
Wind Menu
Damping 0.5 – 10 sec 0.5
Wind Source
Vane, NAV1A, NAV1T,
NAV2A, NAV2T
Vane
Wind Shift (alarm) Off, 1° – 25° Off
Wind Shift Delay 2.0 – 20.0 2.0
Preset Tack Angle 50°120° 90°
Close Haul Def 30° 54° 45°
Close Reach Def 580° 60°
Beam Reach Def 81° – 110° 90°
Broad Reach Def 111° – 159° 120°
Gybe Hold Point 160° – 170° 165°
Table 20 – Default & User Settings