DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS
55Dallmeier electronic
Motion Estimate
This value species the estimated percentage of images with motion. It affects only the
estimated recording duration (Estimate) in the track.
8.4.1.3 Contact
In the Contact recording mode the recording is triggered by the recorder’s contact IN func-
tions. Contrary contact functions or completion of an Option will stop the recording.
Note that a contact input must be congured for the relevant camera (see chapter Contact
IN).
Ø Ensure that the Expert Mode option is activated.
Ø Set the Contact recording mode.
Ø Observe the explanations given below.
Fig. 8-19: Contact recording mode
Ø Congure Private Zones if required (see chapter Basicconguration).
Ø Activate / congure the Camera Timer if required (see chapter Basicconguration).
Ø Activate the Use Database option if required.
Ø Set the Pre-Event time (see above).
Ø Set the Contact Recording Duration if required.
Ø Set the Options for contact recording.
Ø Conrm with OK.
Normal Single
A contact triggers the recording of an individual picture.
Normal sequencer
The recording is triggered by the contact switching. It continues until the contact is released
again.
Start
The recording is triggered by the contact switching. The recording is stopped by an opposite
contact function (Stop recording (Contact recording mode) or Stop recording camera
(Contact recording mode)).