Danfoss VLT AutomationDrive Programming Guide

Danfoss VLT AutomationDrive
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
0-50 LCP Copy
Option: Function:
[3] Size indep. from
LCP
Copy only the parameters that are
independent of the motor size. The
latter selection can be used to
program several adjustable frequency
drives with the same function without
disturbing motor data.
[4] File from MCO to
LCP
[5] File from LCP to
MCO
[6] Data from DYN to
LCP
[7] Data from LCP to
DYN
NOTE!
This parameter cannot be adjusted while the motor is
running.
0-51 Set-up Copy
Option: Function:
[0] * No copy No function
[1] Copy to set-
up 1
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 1.
[2] Copy to set-
up 2
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 2.
[3] Copy to set-
up 3
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 3.
[4] Copy to set-
up 4
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 4.
[9] Copy to all Copies the parameters in the present set-up
over to each of the set-ups 1 to 4.
3.2.7 0-6* Password
0-60 Main Menu Password
Range: Function:
100 * [0 - 999 ] Define the password for access to the main
menu via the [Main Menu] key. If 0-61 Access
to Main Menu w/o Password is set to Full
access [0], this parameter will be ignored.
0-61 Access to Main Menu w/o Password
Option: Function:
[0] * Full access
Disables password defined in 0-60 Main
Menu Password.
[1] LCP: Read only Prevent unauthorized editing of main
menu parameters.
[2] LCP: No access Prevent unauthorized viewing and editing
of main menu parameters.
[3] Bus: Read only Read-only functions for parameters on
Serial communication bus and/or FC
standard bus.
[4] Bus: No access No access to parameters is allowed via
Serial communication bus and/or FC
standard bus.
[5] All: Read only Read-only function for parameters on LCP,
Serial communication bus or FC standard
bus.
[6] All: No access No access from LCP, Serial communication
bus or FC standard bus is allowed.
If Full access [0] is selected then 0-60 Main Menu Password,
0-65 Personal Menu Password and 0-66 Access to Personal
Menu w/o Password will be ignored.
NOTE!
More complex password protection is available for OEMs
upon request.
0-65 Quick Menu Password
Range: Function:
200* [-9999 -
9999 ]
Define the password for access to the quick
menu via the [Quick Menu] key. If
0-66 Access to Quick Menu w/o Password is
set to Full access [0], this parameter will be
ignored.
0-66 Access to Quick Menu w/o Password
Option: Function:
[0] * Full access
Disables the password defined in
0-65 Quick Menu Password.
[1] LCP: Read only Prevents unauthorized editing of quick
menu parameters.
[3] Bus: Read only Read only functions for quick menu
parameters on Serial communication bus
and/ or FC standard bus.
[5] All: Read only read only function for quick menu
parameters on LCP, Serial communication
bus or FC standard bus.
If 0-61 Access to Main Menu w/o Password is set to Full
access [0], then this parameter will be ignored.
Parameter Descriptions FC 300 Programming Guide
MG33MD22 - VLT
®
is a registered Danfoss trademark 3-11
3
3
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx

Table of Contents

Other manuals for Danfoss VLT AutomationDrive

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive and is the answer not in the manual?

Danfoss VLT AutomationDrive Specifications

General IconGeneral
Supply Voltage3 x 200-240 V ±10% 3 x 380-500 V ±10% 3 x 525-600 V ±10%
EnclosureIP20
Output Power Range0.25 kW - 1.5 MW
Communication ProtocolsModbus RTU
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short circuit, Ground fault, Motor overload
Ambient Temperature Range-10°C to +50°C (14°F to 122°F)