15-32 Alarm Log: Time
Array [10]
Range: Function:
0 s* [0 - 2147483647 s] View the time when the logged event
occurred. Time is measured in seconds
from Adjustable frequency drive start-
up.
3.16.5 15-4* Drive Identification
Parameters containing read-only information about the
hardware and software configuration of the Adjustable
frequency drive.
15-40 FC Type
Range: Function:
0* [0 - 0 ] View the Adjustable frequency drive type. The
readout is identical to the FC 300 Series power field
of the type code definition, characters 1-6.
15-41 Power Section
Range: Function:
0* [0 - 0 ] View the FC type. The readout is identical to the FC
300 Series power field of the type code definition,
characters 7-10.
15-42 Voltage
Range: Function:
0* [0 - 0 ] View the FC type. The readout is identical to the FC
300 Series power field of the type code definition,
characters 11-12.
15-43 Software Version
Range: Function:
0 * [0 - 0 ] View the combined SW version (or ‘package
version’) consisting of power SW and control SW.
15-44 Ordered Typecode String
Range: Function:
0 * [0 - 0 ] View the type code string used for re-ordering the
Adjustable frequency drive in its original configu-
ration.
15-45 Actual Typecode String
Range: Function:
0 * [0 - 0 ] View the actual string.
15-46 Frequency Converter Ordering No
Range: Function:
0 * [0 - 0 ] View the 8-digit ordering number used for re-
ordering the Adjustable frequency drive in its
original configuration.
15-47 Power Card Ordering No
Range: Function:
0 * [0 - 0 ] View the power card ordering number.
15-48 LCP Id No
Range: Function:
0 * [0 - 0 ] View the LCP ID number.
15-49 SW ID Control Card
Range: Function:
0 * [0 - 0 ] View the control card software version number.
15-50 SW ID Power Card
Range: Function:
0 * [0 - 0 ] View the power card software version number.
15-51 Frequency Converter Serial Number
Range: Function:
0 * [0 - 0 ] View the Adjustable frequency drive serial number.
15-53 Power Card Serial Number
Range: Function:
0 * [0 - 0 ] View the power card serial number.
15-59 CSIV Filename
Range: Function:
Application
dependent*
[0 - 0 ] Shows the currently used CSIV
(Costumer Specific Initial Values)
filename.
3.16.6 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software configuration of the options
installed in slots A, B, C0 and C1.
15-60 Option Mounted
Range: Function:
0 * [0 - 0 ] View the installed option type.
15-61 Option SW Version
Range: Function:
0 * [0 - 0 ] View the installed option software version.
Parameter Descriptions FC 300 Programming Guide
MG33MD22 - VLT
®
is a registered Danfoss trademark 3-139
3
3
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20872-Danfoss-131H4490-VLT-Automation-VT-Drive-VFD-FC302-460V-25-HP.aspx

Table of Contents

Other manuals for Danfoss VLT AutomationDrive

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive and is the answer not in the manual?

Danfoss VLT AutomationDrive Specifications

General IconGeneral
Supply Voltage3 x 200-240 V ±10% 3 x 380-500 V ±10% 3 x 525-600 V ±10%
EnclosureIP20
Output Power Range0.25 kW - 1.5 MW
Communication ProtocolsModbus RTU
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short circuit, Ground fault, Motor overload
Ambient Temperature Range-10°C to +50°C (14°F to 122°F)