E-GENIUS
94
AV500/AV900 2D CAMERA
Encoder Step (mm/pulse)
Click to activate the Encoder Step input form. Enter the Encoder Wheel Circumference
in the field provided and select the in or mm option. Enter the Pulses / Revolution in the field
provided (See the table below for values). Click Submit to save the values, or click Cancel to
return to the Operating Mode window.
Encoder Step Settings Table
Encoder Wheel
Circumference
PPR
(Pulses Per
Revolution)
Enco
der Step
(mm)
Encoder Step
(inch)
Encoder Model
304.8 mm [12 in] 192 1.5875 16 1000019875
304.8 mm [12 in] 240 1.27 20 1000019875
300 mm [11.81 in] 192 1.5625 16 OEK-2 93ACC1770
300 mm [11.81 in] 240 1.25 20 OEK-2 93ACC1770
304.8 mm [12 in] 2400 0.127 200 OEK-3 93ACC0104
Encoder Resolution
Displays the encoder/tachometer resolution in pulses per inch (PPI) based on the Encoder Step
calculation. This field cannot be edited.
Conveyor Speed (max/constant) (m/sec)
With the Physical Encoder enabled the Conveyor Speed (max/constant) setting must be set 1.5
times the belt speed. As an example if the conveyor is running 2 mps than this parameter must
be set to 3.
Formula: Max conveyor speed x 1.05
This formula is for an external tach. If the unit is set for internal the exact speed of the
conveyor must be entered.
When disabled there is no physical tach connected to the camera. When the unit is set for
internal tack, the exact speed of the conveyor must be enabled. The Max Conveyor Speed
option uses an internal clock that sets the tach to match the conveyor speed.
Advanced Encoder Settings
Direct Encoder
Select Disable or Enable from the drop-down list. Direct encoder is a high-resolution encoder/
tachometer (200 tachs per inch/.012700 mm/pulse) used in start/stop applications.
Frame Rate
Frame Rate
Select an appropriate Frame Rate from the drop-down list.
• 8 frames per second
• 16 frames per second
• 24 frames per second
• 32 frames per second
Conveyor Width
Conveyor Width
This option is adjusted to best fit various applications. Contact Datalogic support to
determine the correct setting.