E-GENIUS
232
AV500/AV900 2D CAMERA
Diagnostics | Device Tracking
Use the Device Tracking window to view encoder/tachometer and trigger event infor-
mation. This will provide information such as start and end trig
ger, transmit point data,
transmit message, sequence number, etc.
To access the Device Tracking window:
1. In the menu tree under Diagnostics, click Device Tracking. The Device Tracking
window opens.
2. Click Start for a continuous feed of Event Type, Seq(uence) Number, Tach(ometer)
Count, and Event Information data.
3. Click Stop to pause
the feed.
4. Click on a TRANSMIT POINT link to view speci
fic transaction data and image of last
package.