• Sync Controller IP (the sync adapter cable must be used):
e-Genius Calibration Presets
Before physical calibration is begun, a few settings need to be confirmed or modified in
e-Genius. Your PC’s IP address needs to match the camera system’s IP Address range,
see section “Accessing e-Genius” on page 79 for information on connecting a laptop to
the ca
meras.
System Info: Bring Each Camera into the Network
When power is applied to the cameras for the first time each camera will need to be
brought int
o the sync network using e-Genius.
1. From the menu tree, navigate to the Modif
y Set
tings | System Info. The System
Info Page opens.
2. From the Action drop-down list, select
the Add to Cluster as new.
3. Click Update t
o add the camera to the This Cluster table.
4. Once each AV500/AV900 has been added under This Cluster, its mounting posi-
ti
ons will need to be identified. Click Blink in a camera’s r
ow in the table. That
camera’s illumination will light.
5. Once the camera has been identified, select its mounting position from the Cam-
era P
osition drop-down list.
6. Click Update t
o save the configuration.
PackTrack Calibration
The following procedure is for PackTrack Mode.
Operating Mode
In the menu tree under Modify Settings, navigate to Global Settings | Operating Mode.
The Operating Mode window opens. See section “Operating Mode” on page 91 for an
explanation of the Operating Mode options.
The following parameters must be set to match the application:
1. Encoder Settings - Encoder Step
Settings: Modify Settings | Global Settings |
Operating Mode > Encoder Step. Conveyor speed: Enter the conveyor speed (For-
mula:
Max conveyor speed x 1.05). This is needed so the AV500/AV900 sets the
exposure time parameter during calibration.
2. Tr
igger Source: Make sure the
Trigger Active State is set correctly, To test this, nav-
igate to Diagnostics | Device
Tracking. Run two boxes through the system. Con-
firm that the start and end trigger corresponds to the correct Seq Numb
er.
3. Transmit Point Settings
Your PC’s IP address needs to match the camera system’s IP Address range, “T
o change
your
PC’s IP Address:” on page 80 for information on connecting a laptop to the system. The
Host and Image port IP addresses may have been changed for your application. Contact