E-GENIUS
142
AV500/AV900 2D CAMERA
ASI Object: Message Options
Message Format
Select ASCII or Binary from the drop-down list.
ASCII - Select to transmit an ASCII barcode message (as defined by the Message Type). The
only difference is that the Header and Trailer are omitted from the barcode messages
transmitted using EtherNet/IP. When ASCII messages are in use, the Byte Swap ASCII Data
selection will swap the high and low byte of data within each 16 bit word. This is useful for
processing data on some Programmable Controllers.
Binary - Select to convert barcode data to a “numeric value” and transferred as a 32 bit
word. The user can specify the byte ordering of this word. If any non-numeric (not ASCII ‘0’ to
‘9’ or leading or trailing space) characters are contained in the barcode, the numeric value is
zero.
ASCII Message Byte Swap
Select the check box to enable the function. Available when Binary is selected from the
Message Format drop-down list. When ASCII messages are in use, the ASCII Message Byte
Swap selection will swap the high and low byte of data within each 16 bit word. This is useful
for processing data on some Programmable Controllers.
Digital Output Lines
Allow PLC to Control Output 1
Click to allow PLC to control Output 1.
Allow PLC to Control Output 2
Click to allow PLC to control Output 2.
Serial Settings
Data Output Protocol
Select one of the following from the drop-down:
Disable
Standard
Advanced
Crisplant
Beumer
Custom 1 - 5
Not Available
WebSentinel
Video Coding (PV v2.4)
SC5000
Trigger Message
Heartbeat Settings
Hearbeat Enable
Select one of the following from the Heartbeat Enable drop-down.
Disable: The Heartbeat message is not transmitted
Unconditional: The Heartbeat message is always transmitted, even if communication is still
active.
Conditional: The Heartbeat message is transmitted only when there is no communication.
Timeout
Enter a time value in seconds to define the amount of time between two heartbeat message
transmissions. The timeout timer determines the period from one message to the next. In the
Conditional setting the timer is reset when either a host message or a heartbeat is sent. In an
If Digital Output Lines are set to Ethernet IP and the poll rate for the PLC is set to less
than 20 ms, message may get missed. Make sure your PLC polling rate is not less than
20 ms.
IDX1 is only for Serial communication through the Serial Host output. IDX2 can be used
for either Serial AUX communication or an Ethernet socket.