Simple Network Management Protocol | 1005
If we learn mac address for the LAG, status will be shown for those as well
dot3aCurAggVlanId
SNMPv2-SMI::enterprises.6027.3.2.1.1.4.1.1.1.0.0.0.0.0.1.1 = INTEGER: 1
dot3aCurAggMacAddr
SNMPv2-SMI::enterprises.6027.3.2.1.1.4.1.2.1.0.0.0.0.0.1.1 = Hex-STRING: 00 00 00 00 00 01
dot3aCurAggIndex
SNMPv2-SMI::enterprises.6027.3.2.1.1.4.1.3.1.0.0.0.0.0.1.1 = INTEGER: 1
dot3aCurAggStatus
SNMPv2-SMI::enterprises.6027.3.2.1.1.4.1.4.1.0.0.0.0.0.1.1 = INTEGER: 1 << Status active, 2 –
status inactive
For L3 lag we don’t have this support.
SNMP trap works fine for L2 / L3 / default mode LAG
SNMPv2-MIB::sysUpTime.0 = Timeticks: (8500842) 23:36:48.42
SNMPv2-MIB::snmpTrapOID.0 = OID: IF-MIB::linkDown
IF-MIB::ifIndex.33865785 = INTEGER: 33865785
SNMPv2-SMI::enterprises.6027.3.1.1.4.1.2 = STRING: "OSTATE_DN: Changed interface state to down: Gi
0/0"
2010-02-10 14:22:39 10.16.130.4 [10.16.130.4]:
SNMPv2-MIB::sysUpTime.0 = Timeticks: (8500842) 23:36:48.42
SNMPv2-MIB::snmpTrapOID.0 = OID: IF-MIB::linkDown
IF-MIB::ifIndex.1107755009 = INTEGER: 1107755009
SNMPv2-SMI::enterprises.6027.3.1.1.4.1.2 = STRING: "OSTATE_DN: Changed interface state to down: Po
1"
2010-02-10 14:22:40 10.16.130.4 [10.16.130.4]:
SNMPv2-MIB::sysUpTime.0 = Timeticks: (8500932) 23:36:49.32 SNMPv2-MIB::snmpTrapOID.0 = OID:
IF-MIB::linkUp IF-MIB::ifIndex.33865785 = INTEGER: 33865785
SNMPv2-SMI::enterprises.6027.3.1.1.4.1.2 = STRING: "OSTATE_UP: Changed interface state to up: Gi
0/0"
2010-02-10 14:22:40 10.16.130.4 [10.16.130.4]:
SNMPv2-MIB::sysUpTime.0 = Timeticks: (8500934) 23:36:49.34 SNMPv2-MIB::snmpTrapOID.0 = OID:
IF-MIB::linkUp IF-MIB::ifIndex.1107755009 = INTEGER: 1107755009
SNMPv2-SMI::enterprises.6027.3.1.1.4.1.2 = STRING: "OSTATE_UP: Changed interface state to up: Po
1"
Troubleshooting SNMP Operation
When you use SNMP to retrieve management data from an SNMP agent on a Dell Force10 router, take
into account the following behavior:
• When you query an IPv4 icmpMsgStatsInPkts object in the ICMP table by using the
snmpwalk
command, the output for echo replies may be incorrectly displayed. Use the
show ip traffic command to
correctly display this information under ICMP statistics in the command output.
• When you query an icmpStatsInErrors object in the icmpStats table by using the
snmpget or snmpwalk
command, the output for IPv4 addresses may be incorrectly displayed. Use the
show ip traffic
command to correctly display this information under IP and ICMP statistics.
• When you query an IPv4 icmpMsgStatsInPkts object in the ICMP table by using the
snmpwalk
command, the echo response output may not be displayed. Use the
show ip traffic command to
correctly display ICMP statistics, such as echo response.

Table of Contents

Other manuals for Dell Force10 C150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Force10 C150 and is the answer not in the manual?

Dell Force10 C150 Specifications

General IconGeneral
BrandDell
ModelForce10 C150
CategoryServer
LanguageEnglish

Related product manuals