Determine the Affect of a Port on the Power Budget
The PoE power budget is affected differently depending on how PoE is enabled and whether a device is 
connected:
1. When you configure a port with 
power inline auto without the max_milliwatts power limit option, power 
is only allocated after you connect a device to the port.
• When you connect a device, the maximum power for the device class is allocated if there is 
sufficient power in the budget. See Table 36-1 on page 785.
• If there is not enough power in the budget, the configuration is maintained and the port waits for 
power to become available.
• If the device advertises its power requirement through LLDP-MED, then FTOS allocates the 
required amount and returns the remaining amount to the budget.
2. When you configure a port with 
power inline auto with the power limit option max_milliwatts, power is 
only allocated after you connect a device to the port.
• If the maximum power for the device class is less than the power limit you specified, FTOS 
allocates the required amount and returns the remaining amount to the budget. 
• If there is not enough power in the budget, the configuration is maintained and the port waits for 
power to become available.
• If the maximum power for the device class is more than than the power limit you specified, FTOS 
does not allocate any power.
3. When you configure a port with 
power inline static without the power limit option (max_milliwatts), 
FTOS allocates 15.4W (subject to availability and priority) to the port whether or not a device is 
connected.
4. When you configure a port with
 power inline static with the power limit option (max_milliwatts), FTOS 
allocates the specified number of Watts. 
• If there is not enough power in the budget, the configuration is maintained and port waits for 
power to become available.
• If the maximum power for the device class is more than than the power limit you specified, FTOS 
does not allocate any power.
Note: LLDP-MED TLVs are only honored if the port is configured with power inline auto (with or without 
the 
max_milliwatts option). 
Note: When a port is configured with power inline auto (with or without the max_milliwatts option) and the 