EasyManua.ls Logo

Dell Force10 C150 - Configuring BFD for Vlans

Dell Force10 C150
1262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
198 | Bidirectional Forwarding Detection
www.dell.com | support.dell.com
To change parameters for a particular VRRP session:
View session parameters using the command
show bfd neighbors detail, as shown in Figure 9-8 on
page 179.
Disabling BFD for VRRP
If any or all VRRP sessions are disabled, the sessions are torn down. A final Admin Down control packet
is sent to all neighbors and sessions on the remote system change to the Down state (Message 3 on
page 179).
To disable all VRRP sessions on an interface:
To disable all VRRP sessions in a particular VRRP group:
To disable a particular VRRP session:
Configuring BFD for VLANs
BFD on Dell Force10 systems is a Layer 3 protocol. Therefore, BFD is used with routed VLANs. BFD on
VLANs is analogous to BFD on physical ports. If no routing protocol is enabled, and a remote system fails,
the local system does not remove the connected route until the first failed attempt to send a packet. If BFD
is enabled, the local system removes the route when it stops receiving periodic control packets from the
remote system.
Step Task Command Syntax Command Mode
1 Change parameters for a particular
VRRP session.
vrrp bfd neighbor ip-address interval
milliseconds
min_rx milliseconds multiplier
value role
[active | passive]
INTERFACE
Step Task Command Syntax Command Mode
1 Disable all VRRP sessions on an
interface.
no vrrp bfd all-neighbors
INTERFACE
Step Task Command Syntax Command Mode
1 Disable all VRRP sessions in a
VRRP group.
bfd disable
VRRP
Step Task Command Syntax Command Mode
1 Disable a particular VRRP session on
an interface.
no vrrp bfd neighbor ip-address
INTERFACE

Table of Contents

Other manuals for Dell Force10 C150

Related product manuals