EasyManua.ls Logo

Dell Force10 C150 - Page 817

Dell Force10 C150
1262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Port Monitoring | 817
Figure 38-3. Number of Monitoring Ports on the C-Series and S-Series
In Figure 38-4, 0/25 and 0/26 belong to Port-pipe 1. This port-pipe again has the same restriction of only
four destination ports, new or used.
Figure 38-4. Number of Monitoring Ports on the C-Series and S-Series
A source port may only be monitored by one destination port (Message 6), but a destination port may
monitor more than one source port. Given these parameters, Figure 38-1 illustrates conceptually the
possible port monitoring configurations on the C-Series and S-Series.
Message 5 One Destination Port in a Monitoring Session Error Message on C-Series and S-Series
% Error: Exceeding max MG ports for this MD port pipe.
Message 6 One Destination Port per Source Port Error Message
% Error: MD port is already being monitored.
FTOS(conf)#mon ses 300
FTOS(conf-mon-sess-300)#source gig 0/17 destination gig 0/4 direction tx
% Error: Exceeding max MG ports for this MD port pipe.
FTOS(conf-mon-sess-300)#
FTOS(conf-mon-sess-300)#source gig 0/17 destination gig 0/1 direction tx
FTOS(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 Gi 0/13 Gi 0/1 rx interface Port-based
10 Gi 0/14 Gi 0/2 rx interface Port-based
20 Gi 0/15 Gi 0/3 rx interface Port-based
30 Gi 0/16 Gi 0/37 rx interface Port-based
300 Gi 0/17 Gi 0/1 tx interface Port-based
FTOS(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 Gi 0/13 Gi 0/1 rx interface Port-based
10 Gi 0/14 Gi 0/2 rx interface Port-based
20 Gi 0/15 Gi 0/3 rx interface Port-based
30 Gi 0/16 Gi 0/37 rx interface Port-based
100 Gi 0/25 Gi 0/38 tx interface Port-based
110 Gi 0/26 Gi 0/39 tx interface Port-based
300 Gi 0/17 Gi 0/1 tx interface Port-based
FTOS(conf-mon-sess-300)#