EasyManua.ls Logo

Digi TransPort WR31 - Page 54

Digi TransPort WR31
866 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware TransPort WR31 hardware
Digi TransPort WR Routers User Guide 54
Analog input specifications
Voltage input mode (default)
Current loop mode
Specification Min Nom Max Units
Resolution .. .. 12 BITS
Accuracy .. .. 0.2 %
Rated Input Voltage -0.2 30 V
Rated Input Current 0 40 mA
Specification Min Nom Max Units
Input Voltage -0.2 .. 10.25 V
Input Impedance .. 291 K .. Ohms
Specification Min Nom Max Units
Minimum Input Voltage .. 2 .. V
Load Resistance .. 200 .. Ohms