Configure alarms Event Settings parameters
Digi TransPort WR Routers User Guide 618
To configure the Event Settings, set the following parameter values:
Only log events with a log priority of at least n
Enables a filter that ensures that only events having a specified severity or lower level are
logged.
Do not log the following events
A numerical list of comma-separated values specifying events to be excluded from the log. These
numerical values can be found in the eventlog.txt file on the router.
After power up, wait s seconds before sending Emails, SNMP traps, SMS or Syslog messages
The delay, in seconds, after power-up that the router should wait before sending any alert
messages. This is useful when the sending of those items would fail if sent too soon after the
router powers up because the underlying interface to use has not completed initialization.
Include event number in the event log and Email, SNMP traps or Syslog messages
If enabled, event numbers from the logcodes.txt file are included.
Related CLI commands
Entity Instance Parameter Values Equivalent web parameter
event n loglevel 0-9
0 none
1 low
9 high
Only log events with a log priority of at
least n
event n ev_filter Comma-separated list of
event numbers
Do not log the following events.
event n action_dly Number of seconds (such as
60)
After power up, wait s seconds before
sending Email, SNMP traps, SMS or
Syslog messages.
event n incevnums 0, 1 Include event number.