Manage networks and connections Use the Analyser
Digi TransPort WR Routers User Guide 801
Related CLI commands (not available via the web interface)
)
Entity Instance Parameter Values Action
ana 0 fcon on, off Enables serial flow control tracing.
ana 0 stopbufs 0-255 Stops Analyser when number of free system
buffers matches this value.
ana 0 stopmsgs 0-255 Stops Analyser when number of free system
messages matches this value.
ana 0 stopflood 0-1 Stops Analyser when Ethernet flood protection is
activated.
ana 0 lowbufcmd Command String Run this command when the number of free
system buffers match lowbuflvel.
ana 0 lowbuflev Integer Displays the free system buffer threshold that
lowbufcmd uses.
ana 0 lowmsgcmd Command String Run this command when the number of free
system messages match lowmsglvel.
ana 0 lowmsglev Integer Displays the free system message threshold that
lowmsgcmd uses.
ana 0 logdrive String Specifies an alternate file system drive on which to
store the Analyser trace. To use an external USB
flash device, this should be set to u:
If the router has an internal SDIO flash device,
select it by specifying s:
ana 0 logfile Filename Stores the Analyser trace in the named file on an
alternate drive.
ana 0 contfile Filename Stores the Analyser trace in the named file on an
alternate drive once the file indicated by logfile is
reaches its max size as specified by logsizek.
ana 0 logsizek Value in Kbytes Sets the maximum size in Kbytes of the file on the
alternate drive.
When set to 0, the file size is only limited by the
flash device.