C
HAPTER
4
| Basic Management Tasks
Telnet Settings
– 109 –
TELNET SETTINGS
Use the System > Telnet menu to configure parameters for accessing the
CLI over a Telnet connection. You can access the onboard configuration
program over the network using Telnet (i.e., a virtual terminal).
Management access via Telnet can be enabled/disabled and other
parameters set, including the TCP port number, time outs, and a password.
Note that the password is only configurable through the CLI.) These
parameters can be configured via the web or CLI interface.
CLI REFERENCES
â—† "Line" on page 520
PARAMETERS
The following parameters are displayed:
◆ Telnet Status – Enables or disables Telnet access to the switch.
(Default: Enabled)
◆ TCP Port – Sets the TCP port number for Telnet on the switch.
(Default: 23)
◆ Login Timeout – Sets the interval that the system waits for a user to
log into the CLI. If a login attempt is not detected within the timeout
interval, the connection is terminated for the session.
(Range: 0-300 seconds; Default: 300 seconds)
◆ Exec Timeout – Sets the interval that the system waits until user input
is detected. If user input is not detected within the timeout interval, the
current session is terminated. (Range: 0-65535 seconds; Default: 600
seconds)
◆ Password Threshold – Sets the password intrusion threshold, which
limits the number of failed logon attempts. When the logon attempt
threshold is reached, the system interface becomes silent for a
specified amount of time (set by the Silent Time parameter) before
allowing the next logon attempt. (Range: 0-120; Default: 3 attempts)
◆ Quiet Period – Sets the amount of time the management interface is
inaccessible after the number of unsuccessful logon attempts has been
exceeded. (Range: 0-65535 seconds; Default: 30 seconds)
N
OTE
:
The password for the Telnet connection can only be configured
through the CLI (see "password" on page 524).
N
OTE
:
Password checking can be enabled or disabled for login to the
console connection (see "login" on page 522). You can select
authentication by a single global password as configured for the password
command, or by passwords set up for specific user-name accounts. The
default is for local passwords configured on the switch.

Table of Contents

Other manuals for Edge-Core ES3510MA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ES3510MA and is the answer not in the manual?

Edge-Core ES3510MA Specifications

General IconGeneral
BrandEdge-Core
ModelES3510MA
CategorySwitch
LanguageEnglish

Related product manuals