C
HAPTER
21
| System Management Commands
Time
– 541 –
COMMAND USAGE
â—† The time acquired from time servers is used to record accurate dates
and times for log events. Without SNTP, the switch only records the
time starting from the factory default set at the last bootup (i.e.,
00:00:00, Jan. 1, 2001).
â—† This command enables client time requests to time servers specified via
the sntp server command. It issues time synchronization requests
based on the interval set via the sntp poll command.
EXAMPLE
Console(config)#sntp server 10.1.0.19
Console(config)#sntp poll 60
Console(config)#sntp client
Console(config)#end
Console#show sntp
Current Time: Dec 23 02:52:44 2002
Poll Interval: 60
Current Mode: unicast
SNTP Status : Enabled
SNTP Server 137.92.140.80 0.0.0.0 0.0.0.0
Current Server: 137.92.140.80
Console#
RELATED COMMANDS
sntp server (542)
sntp poll (541)
show sntp (542)
sntp poll This command sets the interval between sending time requests when the
switch is set to SNTP client mode. Use the no form to restore to the
default.
SYNTAX
sntp poll seconds
no sntp poll
seconds - Interval between time requests.
(Range: 16-16384 seconds)
DEFAULT SETTING
16 seconds
COMMAND MODE
Global Configuration
EXAMPLE
Console(config)#sntp poll 60
Console#

Table of Contents

Other manuals for Edge-Core ES3510MA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ES3510MA and is the answer not in the manual?

Edge-Core ES3510MA Specifications

General IconGeneral
BrandEdge-Core
ModelES3510MA
CategorySwitch
LanguageEnglish

Related product manuals