EasyManua.ls Logo

Edge-Core ECS3510-26P - User Manual

Edge-Core ECS3510-26P
1026 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Management Guide
www.edge-core.com
ECS3510-26P
26-Port Fast Ethernet
Layer 2 Switch

Table of Contents

Other manuals for Edge-Core ECS3510-26P

Questions and Answers

  • J
    jason56Aug 11, 2025
    What to do if I cannot connect to Edge-Core Network Router using Secure Shell?
    • L
      leebrianAug 11, 2025
      If you are unable to connect to the Edge-Core Network Router using Secure Shell (SSH), ensure the SSH server control parameters are correctly configured on the switch, and the SSH client software is properly configured on your management station. Verify that you have generated both an RSA and DSA public key on the switch and exported it to the SSH client, and that the SSH service is enabled. Also, confirm that you have set up an account on the switch for each SSH user, including a username, authentication level, and password, and that you have imported the client's public key to the switch if using public key authentication.
  • J
    John RobertsonAug 22, 2025
    How to fix serial port connection issues with Edge-Core Network Router?
    • L
      Leslie JohnsonAug 22, 2025
      If you cannot access the onboard configuration program of your Edge-Core Network Router via a serial port connection, ensure that your terminal emulator program is set to VT100 compatible with 8 data bits, 1 stop bit, no parity, and a baud rate of 115200 bps. Also, check that the null-modem serial cable conforms to the pin-out connections provided in the Installation Guide.
  • S
    Sarah MillerNov 1, 2025
    How to troubleshoot connection issues with Edge-Core Network Router via Telnet, web browser, or SNMP?
    • R
      Richard VillarrealNov 1, 2025
      If you're having trouble connecting to the Edge-Core Network Router using Telnet, a web browser, or SNMP software, first ensure the device is powered on and that the network cables between your management station and the switch are correctly connected. Verify that you have a valid network connection to the switch and the port you're using hasn't been disabled. Also, check that the VLAN interface, through which the management station connects, has a valid IP address, subnet mask, and default gateway. Make sure your management station's IP address is in the same subnet as the switch's IP interface. If you're connecting via a tagged VLAN group IP address, confirm that your management station and any intermediate switches are configured with the correct tag. If you still cannot connect using T...

Edge-Core ECS3510-26P Specifications

General IconGeneral
ModelECS3510-26P
TypeManaged
PoE Ports24
Switching Capacity128 Gbps
Forwarding Rate95.23 Mpps
MAC Address Table Size16K
VLANs4K
Power Supply100-240VAC, 50-60 Hz
Dimensions440 x 260 x 44 mm
Ports24 x 10/100/1000BASE-T + 2 x 10G SFP+
LayerLayer 2+