C
HAPTER
37
| LLDP Commands
– 924 –
lldp med-fast-start-
count
This command specifies the amount of MED Fast Start LLDPDUs to transmit
during the activation process of the LLDP-MED Fast Start mechanism.
SYNTAX
lldp med-fast-start-count packets
seconds - Amount of packets. (Range: 1-10 packets;
Default: 4 packets)
DEFAULT SETTING
4 packets
COMMAND MODE
Global Configuration
COMMAND USAGE
This parameter is part of the timer which ensures that the LLDP-MED Fast
Start mechanism is active for the port. LLDP-MED Fast Start is critical to
the timely startup of LLDP, and therefore integral to the rapid availability of
Emergency Call Service.
EXAMPLE
Console(config)#lldp med-fast-start-count 6
Console(config)#
lldp
notification-interval
This command configures the allowed interval for sending SNMP
notifications about LLDP MIB changes. Use the no form to restore the
default setting.
SYNTAX
lldp notification-interval seconds
no lldp notification-interval
seconds - Specifies the periodic interval at which SNMP notifications
are sent. (Range: 5 - 3600 seconds)
DEFAULT SETTING
5 seconds
COMMAND MODE
Global Configuration
COMMAND USAGE
â—† This parameter only applies to SNMP applications which use data stored
in the LLDP MIB for network monitoring or management.
â—† Information about changes in LLDP neighbors that occur between SNMP
notifications is not transmitted. Only state changes that exist at the
time of a notification are included in the transmission. An SNMP agent