SNMPv3 Commands
– 592 –
COMMAND USAGE
â—† Local users (i.e., the command does not specify a remote engine
identifier) must be configured to authorize management access for
SNMPv3 clients, or to identify the source of SNMPv3 trap messages
sent from the local switch.
â—† Remote users (i.e., the command specifies a remote engine identifier)
must be configured to identify the source of SNMPv3 inform messages
sent from the local switch.
â—† The SNMP engine ID is used to compute the authentication/privacy
digests from the password. You should therefore configure the engine
ID with the snmp-server engine-id command before using this
configuration command.
â—† Before you configure a remote user, use the snmp-server engine-id
command to specify the engine ID for the remote device where the
user resides. Then use the snmp-server user command to specify the
user and the IP address for the remote device where the user resides.
The remote agent’s SNMP engine ID is used to compute authentication/
privacy
digests from the user’s password. If the remote engine ID is not
first configured,
the snmp-server user command specifying a remote
user will fail.
â—† SNMP passwords are localized using the engine ID of the authoritative
agent. For informs, the authoritative SNMP agent is the remote agent.
You therefore need to configure the remote agent’s SNMP engine ID
before you can send proxy requests or informs to it.
EXAMPLE
Console(config)#snmp-server user steve group r&d v3 auth md5 greenpeace priv
des56 einstien
Console(config)#snmp-server user mark group r&d remote 192.168.1.19 v3 auth
md5 greenpeace priv des56 einstien
Console(config)#
snmp-server view This command adds an SNMP view which controls user access to the MIB.
Use the no form to remove an SNMP view.
SYNTAX
snmp-server view view-name oid-tree {included | excluded}
no snmp-server view view-name
view-name - Name of an SNMP view. (Range: 1-32 characters)
oid-tree - Object identifier of a branch within the MIB tree. Wild
cards can be used to mask a specific portion of the OID string.
(Refer to the examples.)
included - Defines an included view.
excluded - Defines an excluded view.

Table of Contents

Other manuals for Edge-Core ECS3510-26P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS3510-26P and is the answer not in the manual?

Edge-Core ECS3510-26P Specifications

General IconGeneral
BrandEdge-Core
ModelECS3510-26P
CategorySwitch
LanguageEnglish

Related product manuals