FLIR Detection A. Info Pool
18 < P r o p e r t y nam e = L a t i t u d e v a l u e = 3 6 . 0 1 3 3 3 3 u n i t s = de g / >
19 < P r o p e r t y nam e = L a s t S p e c t r u m N u m b e r v a l u e = 53 / >
20 < P r o p e r t y nam e = B a t t e r y L o w v a l u e = fal s e / >
21 < P r o p e r t y nam e = O v e r l o a d v a l u e = fa l s e / >
22 < P r o p e r t y nam e = A l a r m v a l u e = fa l s e / >
23 < P r o p e r t y nam e = D o s e R a t e W a r n i n g va l u e = f a l s e / >
24 < P r o p e r t y nam e = D o s e R a t e A l a r m v a l u e = fal s e / >
25 < P r o p e r t y nam e = D o s e A l a r m v a l u e = f a l s e / >
26 < P r o p e r t y nam e = N e u t r o n C o u n t R a t e W a r n i n g v a l u e = fa l s e / > =
27 < P r o p e r t y nam e = N e u t r o n C o u n t R a t e A l a r m v a l u e = fa l s e / >
28 < P r o p e r t y nam e = S i g m a G a m m a A l a r m va l u e = f a l s e / >
29 < P r o p e r t y nam e = S i g m a N e u t r o n A l a r m v a l u e = fal s e / >
30 < / Up d a t e >\0
Property Elements
As shown, there are multiple
Property
elements in a Status update.
name
For reliability and future compatibility, a parser should not rely on the order of the
Property
elements but should parse the
name
attribute of each
Property
element.
value
For each
Property
element in a status update, the
value
attribute will be either textual
or numerical. Many of those elements with a textual
value
attribute indicate a boolean
state with the value being either
”true”
or
”false”
.
units A
units
attribute will be included when necessary to interpret a numerical
value
at-
tributes. Only some
Property
elements have units.
Line 2:
The (SerialNumber) placeholder in the example will be replaced with the unique serial num-
ber of the FLIR identiFINDER R300 sending the message.
Stabilization (Line 4):
Stabilization is only available on models without LED stabilization.
Dose and Dose Rate units
Any dose
units
will be in either rem or Sievert (Sv) scaled units as required by the FLIR
identiFINDER R300 settings (see 6.31, p. 159). The speciied base unit for some properties
will be dynamically scaled according to the property
value
while others are statically scaled
in the FLIR identiFINDER R300 settings.
identiFINDER
®
R300/en/2014.4(13623)/Feb2015 251