XSCF>
showhardconf
SPARC
M10-4S;

+
Serial:2081229003;
Operator_Panel_Switch:Service;

+
System_Power:On;
System_Phase:Cabinet
Power
On;

Partition#0
PPAR_Status:Running;

BB#00
Status:Normal;
Role:Master;
Ver:2050h;
Serial:2081229003;
starting
maintenance
work
on
the
FRU.
Operation
panel
LEDs
You
can
determine
the
status
of
the
system
by
checking
the
LEDs
on
the
operation
panel.
For
details,
see
"2.4.1
Operation
panel
LEDs."
Rear
panel
LED
You
can
determine
the
status
of
the
system
by
checking
the
CHECK
LED
on
the
rear
panel
of
the
chassis,
which
duplicates
the
CHECK
LED
on
the
operation
panel.
For
details,
see
"2.4.2
LEDs
on
the
rear
panel
(System
locator)."
LED
of
each
FRU
If
an
error
occurs
in
the
hardware
in
the
chassis,
you
can
determine
the
location
of
the
error
by
checking
the
LED
of
the
FRU
that
incorporates
the
failed
hardware.
For
details,
see
"2.4.3
LEDs
on
each
component."
Note
that
some
FRUs,
such
as
memory,
do
not
have
mounted
LEDs.
To
check
the
status
of
a
FRU
that
does
not
have
an
LED,
execute
XSCF
shell
commands
such
as
the
showhardconf
command
from
the
maintenance
terminal.
For
details,
see
"Checking
the
FRU
status"
below.
Checking
error
messages
Display
error
messages
to
check
the
log
information
and
obtain
an
error
overview.
You
can
use
either
of
the
following
two
methods
to
check
the
error
messages:
Checking
error
log
information
using
the
XSCF
shell
For
details,
see
"12.1
Checking
a
Log
Saved
by
the
XSCF"
in
the
Fujitsu
M10/SPARC
M10
Systems
System
Operation
and
Administration
Guide.
Checking
messages
with
Oracle
Solaris
For
details,
see
"12.2
Checking
Warning
and
Notification
Messages"
in
the
Fujitsu
M10/SPARC
M10
Systems
System
Operation
and
Administration
Guide.
Checking
the
FRU
status
Execute
XSCF
firmware
commands
to
determine
the
system
hardware
configuration
and
the
status
of
each
FRU.
-
showhardconf
command
Execute
the
showhardconf
command
to
check
the
information
on
the
FRU
list.
1.
Log
in
to
the
XSCF
shell.
2.
Execute
the
showhardconf
command
to
check
the
FRU
list.
A
faulty
FRU
is
indicated
by
an
asterisk
(*)
at
the
beginning
of
the
line.
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service