CHAPTER 6
79
Routine Printer Maintenance
4/29/10 Rev G
are occurring in order to recover
angled nozzles.
Daily
Maintenance
Solution
250ml bottle Use with Anticon-covered swabs to clean
the printheads at the start and end of
each day, after two hours of idle time
and after four hours of printing time.
Gerber Clean
Solution
125ml bottle Use with foam-tipped swab as part of the
Periodic Maintenance Process on an as-
needed basis (whenever angled nozzles
are prevalent).
All Purpose
wipes
56 count package Use in the ink waste tray to absorb excess
ink.
Anticon®
Gold heavy-
weight, clean
room wipes
300 count package Use with Daily Maintenance Solution to
wipe the printheads during Clean Heads
Procedure and End of Day procedures.
Anticon wipes are the only wipes that
should ever touch the printheads.
Fisher
Scientific
foam-tipped
swabs
50, 250 or 500 count package
Use for cleaning the printheads. These
non-scratching, lint free swabs are the
only swabs recommended for the Solara
ion printhead.
CAUTION: It is very important to use only Gerber-recommended wipes and swabs
when cleaning the printheads. Use of wipes and swabs other than what is
recommended could damage the printheads. Be aware that damage caused by use of
unapproved swabs or wipes will not be covered under the standard 12 month
warranty for the Solara ion or a Gerber Service Contract. Always use new, clean
wipes and swabs on different colored printheads. Never reuse wipes and swabs.
Never substitute paper towels for wipes. Dispose of used swabs and wipes
according to local laws and regulations.
CAUTION: Use impervious gloves to protect your hands. Nitrile gloves of no less
than 8 mils have proven impervious for one hour of exposure. Gloves should be
disposed of after one hour of exposure time. Wear safety goggles to protect your
eyes. Dispose of used gloves according to local laws and regulations.
Gerber Solara ion
V
Regular Preventive Maintenance
Following is a chart of recommended regular maintenance to be performed by the owner to ensure
continued print quality and trouble-free operation. Refer to specific instructions on recommended routine
maintenance procedures in this manual.
]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gerber Solara ion and is the answer not in the manual?

Gerber Solara ion Specifications

General IconGeneral
BrandGerber
ModelSolara ion
CategoryPrinter
LanguageEnglish

Related product manuals