Item Description
Number of PGs The number of the parity groups having the logical volumes that can be accessed
through the port
Number of DKBs The number of the disk boards controlling the parity group that contains the logical
volumes that can be accessed through the port
Power Consumption report
The following figure shows an example of a power consumption report. A
record is created every two hours for each power consumption and
temperature monitoring data. The table following the figure describes the
items in the report.
No records are created during a system power failure or if the breakers are
turned off. If the system is in maintenance mode or the SVP is rebooted, up
to two hours of records could be lost.
If a failure occurs in the storage system, the correct information might not be
output.
Item
Description
Date and Time Date and time when power consumption and
temperature were recorded for the two-hour
period
Power Consumption Average (W) Average of the power consumption
Power Consumption Maximum (W) Maximum of the power consumption
Power Consumption Minimum (W) Minimum of the power consumption
TEMP:DKC0-Cluster1 Average (degrees C) Average temperature of DKC0:CL1
TEMP:DKC0-Cluster1 Maximum (degrees C) Maximum temperature of DKC0:CL1
Examples of storage configuration reports 295
System Administrator Guide for VSP Gx00 models and VSP Fx00 models