Item Description
DB47 DBPS472
Temperature maximum value
Maximum temperature (°C) for the two-hour
period of DB47 DBPS472
For VSP G200, item shows up to DB07 DBPS072.
For VSP G400, VSP G600, VSP F400, VSP F600,
item shows up to DB23 DBPS232.
Note: An item name is displayed as DBxx DBPSxxy. The names are listed in
ascending order of the DB number. See DkuTempInfo.csv on page 320 for
locations and values for DBxx and DBPSxxy.
DkuTempMinInfo.csv
This CSV file contains information about DB temperature for every two hours.
A record is DB temperature information obtained from the environment
monitor. A record output to the first line shows the latest temperature
information. Because DB temperature information is measured by DBPS,
items are displayed in this unit*.
DkuTempMinInfo.csv shows the minimum temperature as DB temperature
data. The total number of items depends on the following model:
• VSP G200: 17
• VSP G400/VSP G600/VSP F400/VSP F600: 49
• VSP G800/VSP F800: 97
The DB temperature data displayed in DkuTempAveInfo.csv (average
temperature only), DkuTempMaxInfo.csv (maximum temperature only), and
DkuTempMinInfo.csv (minimum temperature only) is the same value as the
DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is
output every two hours might not contain data for the period. If a failure
occurs in the storage system, the correct information might not be output.
Table 28 DkuTempMinInfo.csv file (Title: <<DB temperature minimum
value Information>>)
Item Description
Date
Year, month, and date when temperature data
was acquired in the format:
YYYY/MM/DD hh:mm:ss
DB00 DBPS001
Temperature minimum value
Minimum temperature (°C) for the two-hour
period of DB00 DBPS001
DB47 DBPS472
Temperature minimum value
Minimum temperature (°C) for the two-hour
period of DB47 DBPS472
For VSP G200, item shows up to DB07 DBPS072.
Examples of storage configuration reports 323