Item Description
Drive Type-Code The type code of the drive in the parity group.
• The type code of the first drive in the parity group.
• If the parity group contains external volumes, the drive type code displays the
vendor, the model, and the serial number of the storage system.
• Separated by semicolons (;) if multiple drive types are set.
Drive Type/RPM Drive type and revolutions-per-minute (RPM) of the drive in the parity group
1
A hyphen (-) is displayed instead of the RPM when the drive is an SSD.
Drive Capacity Capacity of the drive in the parity group
1
RAID Concatenation #0 The number indicating a parity group #0 connected to this parity group
1,2
RAID Concatenation #1 The number indicating a parity group #1 connected to this parity group
1,2
RAID Concatenation #2 The number indicating a parity group #1,2 connected to this parity group
1,2
Encryption Indicates whether the parity group is encrypted.
• For internal volumes: Enabled (encrypted) or Disabled (not encrypted)
• For external volumes: A hyphen (-) is displayed
Accelerated Compression Accelerated compression of the parity group
• If accelerated compression is supported, Enabled or Disabled is displayed.
• If accelerated compression is not supported, a hyphen (-) is displayed.
Notes:
1. A hyphen is displayed if the parity group contains external volumes.
2. A hyphen is displayed if the parity group is not connected with another parity group or if the parity group
contains external volumes including volumes for FICON DM.
Physical Devices report
The following figure shows an example of part of a Physical Devices report.
The actual report includes more columns of information. A record is created
for each physical device. The table following the figure describes the items in
the report.
Examples of storage configuration reports 291
System Administrator Guide for VSP Gx00 models and VSP Fx00 models