Translation of Original Operating Manual 156319-04 159
ADVICE
If the master switch (13) is switched
off, the hydraulic functions are
blocked. This prevents an inadvertent
actuation of hydraulic switches or the
joystick from moving the attachment.
Use transport protection when travel-
ling on roads.
Adjusting volume flow 0 to 25 l/min
C270_079a
14
14
You can control the volume flow for all hydraulic
functions that are operated by buttons jointly using
the potentiometer (14). Other than joystick move-
ments; they are proportional.
1. Turning potentiometer (14) to the left throt-
tles the volume low.
2. Turning potentiometer (14) to the right in-
creases the volume flow.