Translation of Original Operating Manual 156319-04 179
Switching degree of relief (SP1) to actual
pressure in the hydraulic cylinder
mode
HYDAC
mode
HYDAC
mode
HYDAC
mode
HYDAC
mode
HYDAC
mode
HYDAC
Menu Prn Acr
SP1 END YES
C270_148
The degree of relief (SP1) can also be switched to
the actual pressure in the hydraulic cylinder.
1. Switch off the ignition.
2. Press (mode) button and simultaneously
switch on the ignition.
3. Press (mode) button until "Menu" appears in
the display. Release button.
4. Press (mode) button until "Prn" appears in
the display.
5. The Acr or SP1 value is selected with the left
or right button (triangle).
Acr Actual pressure in the hydraulic cylinder
SP1 Degree of relief
6. Press (mode) button until "END" appears in
the display.
7. Select "YES" with the left or right button (tri-
angle).
8. The value is stored after 2 seconds and the
display switches to normal display mode.