EasyManua.ls Logo

Holder C270 - Single maintenance after 50 or 500 operating hours

Default Icon
273 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance schedule C250 ... C370
262 Translation of Original Operating Manual 156319-04
Single maintenance after 50 or 500 operating hours
Customer service at your Holder service partner necessary
Due Maintenance work
Single main-
tenance af-
ter the first
50 operating
hours
Change motor oil and filter
Check heater and air conditioner (hoses) for leaks and function
Check coolant level, top up if necessary
Check V-belts for tension and condition
Replace cartridge of the return flow suction filter for vehicle hydraulics, implement
servopump, volume divider II (replacement mandatory after 50 hours).
Check hydraulic lines and hoses for damage and leaks
Check hydraulic oil level, top up if necessary
Check service and parking brakes, retighten wheel nuts
Retighten threaded connections according to torque table
Single main-
tenance af-
ter the first
500 operating
hours
Change hydraulic oil
Clean suction filter of the driving and working hydraulics, replace if necessary

Table of Contents

Other manuals for Holder C270