Maintenance schedule C250 ... C370
262 Translation of Original Operating Manual 156319-04
Single maintenance after 50 or 500 operating hours
Customer service at your Holder service partner necessary
Due Maintenance work
Single main-
tenance af-
ter the first
50 operating
hours
•
Change motor oil and filter
•
Check heater and air conditioner (hoses) for leaks and function
•
Check coolant level, top up if necessary
•
Check V-belts for tension and condition
•
Replace cartridge of the return flow suction filter for vehicle hydraulics, implement
servopump, volume divider II (replacement mandatory after 50 hours).
•
Check hydraulic lines and hoses for damage and leaks
•
Check hydraulic oil level, top up if necessary
•
Check service and parking brakes, retighten wheel nuts
•
Retighten threaded connections according to torque table
Single main-
tenance af-
ter the first
500 operating
hours
•
Change hydraulic oil
•
Clean suction filter of the driving and working hydraulics, replace if necessary