To remove a completed batch or procedure
1. From either the summary display or the activity table in a custom display, select a batch
or procedure in the Post Exec state that you would like to remove.
2.
Click the (Remove) at the bottom left of the summary grid. If you do not have a set of
activity command buttons you can access the activity commands by right-clicking on
the batch or procedure in the Activity table.
The batch or procedure is removed from the summary.
If you would like to review the report parameters for a completed batch or procedure,
you can check through the captured event data or use the Procedure Analyst product.
Aborting a batch or procedure
You can Abort a running batch or procedure from either the summary display or from an
activity table on a custom display.
To abort a batch or procedure
1. From either the summary display or the activity table on a custom display, select the
batch or procedure to be aborted.
2.
Click the (Abort) at the bottom left of the summary grid. If you do not have a set of
activity command buttons you can access the activity commands by right-clicking on
the batch or procedure in the Activity table.
The batch or procedure moves into the Aborted state.
Executing an activity, batch, or procedure from a custom display
A set of controls has been created and added to HMIWeb Display Builder to enable control
of batches or procedures from custom displays. Most of these controls can be used for any
sequence application and so are called procedure and sequence controls.
This section details these controls and provides explanations of the indicators included on the
controls.
Command button control
You can use the command button control to send a command to a procedure. If control
confirmation has been configured, the Control Confirmation dialog box will be displayed to
capture confirmation before the command is sent to the procedure.
The following image displays an abort command button control.
Operating a batch or procedure
Honeywell 2017 268

Table of Contents

Other manuals for Honeywell Experion LX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Experion LX and is the answer not in the manual?

Honeywell Experion LX Specifications

General IconGeneral
BrandHoneywell
ModelExperion LX
CategoryControl Systems
LanguageEnglish

Related product manuals