COMMISSIONING
Part No.: 4417340 Revision 1 Service Manual 231
954 SmartServo FlexLine
7.4 Configuring the servo gauge
To get the gauge fully operational several gauge and tank related
entities must be configured properly (refer to Figure 7-40).
Entity name Entity name
(SmartView)
Description
[Displacer type] [Displacer type]
(board)
Select the correct displacer type. This will configure
several displacer related parameters automatically.
Note: only for density displacers 0815350 and 0815355
configuring additional settings is needed. In this case
entities [Displacer weight] and [Displacer volume] need
to be configured according to the engraved values.
Note: on the SmartView only the 7 mostly used
selections are selectable. For other displacers please
use Engauge.
[Measuring range and
wire type]
[Wire & drum type]
(board)
Select the correct measuring range and wire type. This
will configure several wire and drum related parameters
automatically.
Note: on the SmartView only the 7 mostly used
selections are selectable. For other wires and drums
please use Engauge.
[Drum circumference] [Drum circum.]
(Product level)
Check whether the pre-programmed drum circumference
is in accordance with the engraved value of the installed
measuring drum.
If that is not correct, enter the engraved drum
circumference.
Note: the unit of the drum circumference is fixed in [mm]!
[Tank top level] [Tank top level]
(Product level)
The tank top level must be set for correct
compensations. The value you enter now, is overwritten
when the level calibration with tank top reference stop is
used (refer to 7.6.2).
[Motor limit switch
high]
[Motor limit high]
(Product level)
This is the highest allowed position for the displacer
during normal operation.
[Motor limit switch
low]
[Motor limit low]
(Product level)
This is the lowest allowed position for the displacer
during normal operation.
[Lock test motor limit
switch level]
[LT switch level]
(Product level)
Sets the highest displacer position during a lock test
[Reference level] [Reference level]
(Product level)
Approximate position of the displacer
[Reset board] [Reset TII-SRV]
(board)
Reset TII-SRV