COMMISSIONING 
 
Part No.: 4417340 Revision 1  Service Manual    231 
  954 SmartServo FlexLine 
7.4   Configuring the servo gauge 
 To get the gauge fully operational several gauge and tank related 
entities must be configured properly (refer to Figure 7-40). 
Entity name  Entity name 
(SmartView) 
Description   
[Displacer type]  [Displacer type] 
(board) 
Select the correct displacer type. This will configure 
several displacer related parameters automatically.  
Note: only for density displacers 0815350 and 0815355 
configuring additional settings is needed. In this case 
entities [Displacer weight] and [Displacer volume] need 
to be configured according to the engraved values. 
Note: on the SmartView only the 7 mostly used 
selections are selectable. For other displacers please 
use Engauge. 
[Measuring range and 
wire type] 
[Wire & drum type] 
(board) 
Select the correct measuring range and wire type. This 
will configure several wire and drum related parameters 
automatically.  
Note: on the SmartView only the 7 mostly used 
selections are selectable. For other wires and drums 
please use Engauge. 
[Drum circumference]  [Drum circum.] 
(Product level) 
Check whether the pre-programmed drum circumference 
is in accordance with the engraved value of the installed 
measuring drum. 
If that is not correct, enter the engraved drum 
circumference. 
Note: the unit of the drum circumference is fixed in [mm]! 
[Tank top level]  [Tank top level] 
(Product level) 
The tank top level must be set for correct 
compensations. The value you enter now, is overwritten 
when the level calibration with tank top reference stop is 
used (refer to 7.6.2). 
[Motor limit switch 
high] 
[Motor limit high] 
(Product level) 
This is the highest allowed position for the displacer 
during normal operation. 
[Motor limit switch 
low] 
[Motor limit low] 
(Product level) 
This is the lowest allowed position for the displacer 
during normal operation. 
[Lock test motor limit 
switch level] 
[LT switch level] 
(Product level) 
Sets the highest displacer position during a lock test 
[Reference level]  [Reference level] 
(Product level) 
Approximate position of the displacer 
[Reset board]  [Reset TII-SRV] 
(board) 
Reset TII-SRV