COMMISSIONING 
 
Part No.: 4417340 Revision 1  Service Manual    77 
  954 SmartServo FlexLine 
Name  Value Range  Default Value  Explanation 
[Lock test stop level]    <0.0> 
Determines the level to which 
the displacer goes after a 
Lock to level, Lock test to 
level or Test command. 
[Lock to level]     
This command sends the 
displacer to the [Lock test 
stop level] and remains 
there. 
[Lock test to level]     
This command sends the 
displacer to the [Lock test 
stop level] and when 
reached, issues an Unlock 
command and the displacer 
returns to the selected 
interface. 
[Test]    
This command sends the 
displacer to the [Lock test 
stop level] and when 
reached, issues a Block 
command and after some 
time issues an Unlock 
command and the displacer 
returns to the selected 
interface. 
[Water interface dip]     
This command searches for 
the water level and after that 
returns to the default 
operation mode. 
[CIU water interface 
dip] 
 
This command searches for 
the water level and stays 
there.