SYSTEM CONFIGURATION
68
Alarms can be used in simple applications to start a Sequence thus switching a camera
to a monitor, displaying text on a screen, activating a control output, sounding a keyboard
alarm, and "flashing" an Icon on an associated GUI (Graphical User interface).
Alarms can also be assigned to an Alarm Queue.
The fields necessary to configure Alarms are on the Alarms screen.
Figure 3-18 Alarms – General Configuration
Field Definitions
Field Description
HEADER
Alarm Number Physical address of the Alarm Input as determined by the
device it is connected to (Alarm 1-6000 are on GPIO
address 1-250, Alarm 6001-6256 are on alarm concentrators
1-16).
DESCRIPTION
Alarm Name The name assigned to this alarm channel.
Short Name Short name assigned to this alarm channel.
ENABLED
Check the box to enable monitoring of this alarm input.
Leaving the box unchecked is a quick method of disabling
an alarm producing erroneous signals.
CONTACT OPEN
Enabled When this box is checked, the Sequence is activated when
the Contact Opens.
Heading
General tab

Table of Contents

Other manuals for Honeywell VideoBloX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell VideoBloX and is the answer not in the manual?

Honeywell VideoBloX Specifications

General IconGeneral
BrandHoneywell
ModelVideoBloX
CategoryMatrix Switcher
LanguageEnglish

Related product manuals