5-163
Hardkey and Softkey Reference
Sweep/List
Sweep Repeat Single Cont
This softkey toggles the sweep repetition between single sweep or continuous
sweep types. The sweep and point triggers will then trigger the sweep.
Softkey Location: Press
Sweep/List, Sweep Repeat Single Cont
Status after Normal Preset: Single
SCPI Commands:
:INITiate:CONTinuous[:ALL] ON|OFF|1|0
:INITiate:CONTinuous[:ALL]?
Sweep Trigger
Pressing this softkey reveals a menu of choices for triggering a full sweep. You
can choose triggering that occurs immediately once a sweep is armed, triggering
that is supplied by the HP-IB, triggering on either the positive or negative edge of
a signal supplied to the TRIGGER IN connector, or triggering by the front panel
Trigger key.
Softkey Location: Press
Sweep/List, More (1 of 2), Sweep Trigger
Status after Normal Preset: Immediate
SCPI Commands:
:TRIGger[:SEQuence]:SOURce |BUS|IMMediate|EXTernal|KEY
:TRIGger[:SEQuence]:SOURce?
Sweep Type List Step
This softkey toggles the sweep type from list sweep to step sweep. You create a
list sweep by supplying the frequency, amplitude, and dwell time for each point in
the sweep. You create a step sweep by supplying the start and stop frequency and
amplitude, the number of points, and a dwell time. The signal generator then
calculates the points between the first and last point in a linear manner.
Softkey Location: Press
Sweep/List, Sweep Type List Step
Status after Normal Preset: List
SCPI Commands:
[:SOURce]:LIST:TYPE LIST|STEP
[:SOURce]:LIST:TYPE?