9-11
Specifications
HP ESG Series Signal Generators Specifications
Amplitude Modulation at fc > 500 kHz
AM is typical above 3 GHz.
Paths: ΦM 1 and ΦM 2 are summed internally for composite modulation.
Either path may be switched to any one of the modulation sources:
Int, Ext 1, Ext2. The ΦM 2 path is limited to a maximum rate of
1MHz. The ΦM 2 path must be set to a deviation less than ΦM 1.
Range (envelope peak maximum specified power): 0 to 100%
Rates (3 dB bandwidth): dc/10 Hz to 10 kHz
Resolution: 0.1%
Accuracy (1 kHz rate): < ±(5% of setting + 1%)
Distortion (1 kHz rate, THD):
30% AM: < 1.5%
90% AM: < 4%
External Inputs: Ext 1 or Ext 2
Sensitivity: 1 Vpk for indicated depth
Input Impedance: 50 , nominal
Paths: AM 1 and AM 2 are summed internally for composite modulation.
Either path may be switched to any one of the modulation sources:
Int, Ext 1, Ext 2.