5-158
Hardkey and Softkey Reference
Sweep/List
Manual Mode Off On
This softkey toggles manual selection of the current sweep point on and off. When
Manual Mode is On, the selected sweep/list point controls the frequency and
amplitude according to the sweep type. The current point in the sweep is
displayed in the active entry area and also below the
Manual Point softkey. This
softkey is disabled when
Sweep is set to Off.
Softkey Location: Press
Sweep/List, More (1 of 2), Manual Mode Off On
Status after Normal Preset: Off
SCPI Commands:
[:SOURce]:LIST:MODE AUTO|MANual
[:SOURce]:LIST:MODE?
Manual Point
Press this softkey to choose a point in the sweep list. When Manual Mode is On, the
selected sweep/list point controls the frequency and amplitude according to the
sweep type. The current point number is shown in the active entry area when you
press
Manual Point. The frequency of the point is shown in the frequency area of
the display. The amplitude of the point is shown in the amplitude area of the
display. You can choose which point to sweep using the up and down arrow keys,
the front panel knob, or by entering the point number desired using the numeric
keypad and pressing the
Enter terminator softkey. This softkey is disabled when
Manual Mode Off On is set to Off.
Softkey Location: Press
Sweep/List, More (1 of 2), Manual Point
Status after Normal Preset: 1
SCPI Commands:
[:SOURce]:LIST:MANual <val>
[:SOURce]:LIST:MANual?

Table of Contents