5-41
Hardkey and Softkey Reference
FM
FM Rate
Use this softkey to change the internal modulation frequency for the FM Path 1
and
FM Path 2 configurations. To change the value, press the softkey once. The
current value for FM rate is displayed in the active entry area. To enter a new
value, rotate the front panel knob until the desired value is displayed, use the up
and down arrow keys, or enter the value using the numeric keypad and press the
Hz or kHz terminator softkey. The range of values allowed is 0.1 Hz to 10 kHz.
(0.1 Hz to 50 kHz is the range allowed if sinewave is selected as the internal
waveform.) The minimum increment allowed is 0.1 Hz. Notice that the new value
of FM rate applies only to whichever FM path configuration you have currently
selected.
Softkey Location: Press
FM/ΦM, FM Rate
Status after Normal Preset: 400 Hz
SCPI Commands:
[:SOURce]:FM[1]|2:INTernal[1]:FREQuency <val><unit>
[:SOURce]:FM[1]|2:INTernal[1]:FREQuency?