5-8
Hardkey and Softkey Reference
AM
AM Start Rate
Use this softkey to change the starting internal modulation frequency for
swept-sine amplitude modulation. To change the value, press the softkey once.
The current value for the AM start rate is displayed in the active entry area. To
enter a new value, rotate the front panel knob until the desired value is displayed,
use the up and down arrow keys, or enter the value using the numeric keypad and
press the
Hz or kHz terminator softkey. The range of values allowed is 0.1 Hz to 50
kHz. The minimum increment allowed is 0.1 Hz.
This softkey is coupled to the
AM Rate softkey in the initial AM Menu and the
AM Tone 1 Rate softkey in the AM Dual-Sine Menu. Any value set for
AM Start Rate is reflected in the AM Rate and AM Tone 1 Rate softkeys. Conversely,
if you change the value for either the
AM Rate softkey or the AM Tone 1 Rate
softkey, the value for
AM Start Rate is changed to match.
Softkey Location: Press
AM, AM Waveform, Swept-Sine, AM Start Rate
Status after Normal Preset: 400.0 Hz
SCPI Commands:
[:SOURce]:AM[1]|2:INTernal[1]:FREQuency <val><unit>
[:SOURce]:AM[1]|2:INTernal[1]:FREQuency?