5-147
Hardkey and Softkey Reference
Sweep/List
Sweep/List
Pressing the front panel Sweep/List key reveals a menu of softkeys. Using these
softkeys you can define a series of points containing frequency, amplitude and
dwell time information for the signal generator to sweep. The softkeys are
described in this section in alphabetical order.
# Points
Press this softkey to define the number of points in a step sweep. To enter the
number of points in the sweep, press
# Points. The number of step sweep points
becomes the active function and the current value is shown in the active entry
area. To enter a new value, rotate the front panel knob until the desired value is
displayed, use the up and down arrow keys, or enter the value using the numeric
keypad and press the
Enter terminator softkey. A step sweep must always have a
minimum of 2 points and can be configured to have as many as 401 points.
Softkey Location: Press
Sweep/List, Configure Step Sweep, # Points
Status after Normal Preset: 2
SCPI Commands:
[:SOURce]:SWEep:POINts <val>
[:SOURce]:SWEep:POINts?

Table of Contents

Other manuals for HP ESG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ESG Series and is the answer not in the manual?

HP ESG Series Specifications

General IconGeneral
BrandHP
ModelESG Series
CategoryPortable Generator
LanguageEnglish

Related product manuals