measurement in each position of the INS, checks accuracy angles
“Accuracy checking points” and chooses the sensor, with the help of which
the temperature control “Temperature Sensor” will be carried out. The
minimal size of parameter “Accumulation Time” 1 changes on 1 with the
help of arrows or by means of necessary value keyboard input. The default
value is 20.
At accuracy tests it is possible to take into account misalignment angles of
the INS installation on a test bench platform on which INS is tested. Such
situation is possible if for INS installation on a test bench platform
intermediate adaptations are used, for example tilter. If deviation angles of
tilter adjusting bases for INS relatively to test bench platform are known,
they are necessary for considering at accuracy check. For this purpose
“Tilter” fields are used in the right bottom window corner Fig. 8.4. Here it is
possible:
- “(None)” is not to consider deviations of bases;
- “(Auto)” is to consider deviations for tilter used for Inertial Labs internal
tests “Tilter №” and a corresponding cell (“Position”) in this tilter;