EasyManuals Logo

Inficon HAPSITE ER User Manual

Inficon HAPSITE ER
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
2 - 2
HAPSITE ER Operating Manual
2.2 Specifications
Operating temperature range . . . . . . . 5°C to 45°C (41°F to 113°F)
Dimensions (LxWxH) . . . . . . . . . . . . . 46 cm x 43 cm x 18 cm
(18 in. x 17 in. x 7 in.)
Weight . . . . . . . . . . . . . . . . . . . . . . . . 19 kg (42 lb) with battery
Battery Life . . . . . . . . . . . . . . . . . . . . . Approximately 2 to 3 hours
(using the Air Probe)
Power Requirement . . . . . . . . . . . . . . 24 V(dc),
30 watts at normal operating conditions
Hard Drive . . . . . . . . . . . . . . . . . . . . . . . 16 GB internal storage
Flash Drive . . . . . . . . . . . . . . . . . . . . . . . USB
Display . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 in. VGA color display with touch
screen
Mass Range . . . . . . . . . . . . . . . . . . . . 41-300 amu (1-300 using SIM)
Scan Rate. . . . . . . . . . . . . . . . . . . . . . up to 1000 amu/sec at
10 points per amu
Ionization Mode . . . . . . . . . . . . . . . . . 70 eV Electron Impact
Carrier Gas. . . . . . . . . . . . . . . . . . . . . Nitrogen
Column Temperature Range . . . . . . . . 45°C to 200°C (113°F to 392°F)
Maximum Sample
Moisture Content . . . . . . . . . . . . . . . . . . 8% by weight
pH Range of Sample . . . . . . . . . . . . . . . 2 to 11
Boiling Point of Sample (approx) . . . . . . <270°C (<51F)
Vapor Pressure of Sample (approx) . . . . 0.01-250 mmHg
GC Column . . . . . . . . . . . . . . . . . . . . . . 5% diphenyl/95% dimethyl polysiloxane
phase, 15 m x 0.25 mm i.d. x 1.0 m df
SIM Channels . . . . . . . . . . . . . . . . . . . Option to enter mass fragments for up
to 10 compounds
External Communications . . . . . . . . . . 802.11G wireless or direct Ethernet
connection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inficon HAPSITE ER and is the answer not in the manual?

Inficon HAPSITE ER Specifications

General IconGeneral
Mass Range1 to 300 amu
TypePortable Gas Chromatograph-Mass Spectrometer (GC-MS)
Operating Temperature Range0° to 40°C (32° to 104°F)
Power Supply110-240 VAC, 50/60 Hz
Data StorageInternal memory with USB export capability
Sample IntroductionDirect Air, Thermal Desorption
Humidity Range0 to 95% non-condensing
TechnologyGas Chromatography - Mass Spectrometry (GC-MS)
ConnectivityUSB, Ethernet